Introduction | Process Heat & Control Systems | Tubular Heaters | Pipe Plug Immersion Heaters | Flanged Immersion Heaters | Circulation Heaters | Heat Transfer Systems | Over-The-Side Immersion Heaters | Boiler & Water Heaters | Pipe Insert Heaters | Quartz Immersion Heaters | Bottom Mount Immersion Heaters | Dishwasher Heaters | Sink Sanitizer Immersion Heaters | Drum Heaters | Process Air Heaters | Enclosure Heaters


MIGHTY-BLADE FORMING

The unheated area from the termination end to the initial bend along with minimum dimensional requirements are primary considerations when forming a Mighty-Blade element. Parameters of the five possible types of bends are shown for use when designing a Mighty-Blade.

click on any Axis Bends to enlarge
Tolerances and Limitations:
Width: 1.0" + .015" -.010"
Thickness: .275" ±.005"
Minimum Sheath Length: 12"
Maximum Sheath Length: 180"
Maximum Voltage: 480
Maximum Amps: 40
Minimum Ohms/In. of EHL:
Mini2 coil element, .075 ohms;
Mini3 coil element, .05 ohms
Maximum Ohms/In. of EHL:
Mini2 coil element, 3.5 ohms;
Mini3 coil element, 2.33 ohms
Unheated Area Each End: 1" minimum; 12" maximum
Wattage: +5 -10%
Resistance: +10 -5%
Sheath Length: ±1/2%
Effective Heated Length: ±1%



home
| about ogden | products { flexible heaters & band heaters | insertion heaters | process electric heaters | strip heaters & mini-tubular heaters | radiant heaters | controls, sensors & accesories } | what's new | contact ogden

OGDEN MANUFACTURING CO.
103 Gamma Drive, Pittsburgh, PA 15238
phone 800-OMC-4921 or 412-967-3906