Transition
Bending

Mounting brackets or stop washers
in unheated area Consult Ogden. |
Watt
Density
To determine watt density, cold areas need be subtracted from
the Sheath Length to determine the Effective Heated Length. A
1-3/4" cold area exists at the bottom end of the Maxi-Zone,
and a 1" cold area is necessary between zones. The cold
area required at the termination area depends upon the ambient
temperature. The minimum cold area is generally 18% of the entire
heated length and is increased as the ambient temperature increases.
Consult Ogden for design assistance based upon application requirements. |