FLANGED HEATERS

Mighty Watt
Cartridge Heaters can be manufactured with flanged located at
any point along sheath with adequate unheated area. Type W flanged
can also be attached to Fig. U unheated section on stock items. |
CONDUIT COUPLER PROTECTION
Flexible conduit is attached with a copper coupler
over-lapping the heater by 1/4". Leads are 14" long
and cable 12" unless specified.
Fig. 1B and 1C can be attached to stock items. |
 |
 |
|
* Standard cold
sections can be reduced or increased
| Diameter |
Minimum
Unheated* |
| Fig.
1B |
Fig.
1C |
| 1/4" |
1/8" |
1/8" |
| 3/8" |
7/8" |
7/8" |
| 1/2" |
7/8" |
7/8" |
| 5/8" |
7/8" |
7/8" |
| 3/4" &
larger |
7/8" |
7/8" |
| Diameter |
A |
B |
Cable
O.D. |
| 1/4" |
3/4" |
7/8" |
1/4" |
| 3/8" |
3/4" |
15/16" |
3/8" |
| 1/2" |
1" |
1-3/16" |
3/8" |
| 5/8" |
1-1/16" |
1-7/16" |
1/2" |
| 3/4"
& larger |
1-5/16" |
1-7/8" |
1/2" |
|
.
Additional Variations |
 |
Special Wattage
Distribution. Specify percentage of overall wattage and length
for each section. Typically, the entire lenght is divided into
thirds with the overall wattage split into the following percentages:
40% at lead and bottom third of length with 20% in the middle,
or, 35% at lead and bottom third of length with 30% in the middle. |
|
 |
Fiberglass Sleeving |
 |
Teflon® Sleeving |
 |
FormedConsult Ogden |
 |
Centerless Grinding of Sheath
to Precision Diameter |
|
 |
Passivation |
 |
Special Unheated
Area |
 |
Ground Lead |
 |
Ceramic Bead Insulation |
 |
Built-in Thermostat
or Thermal-Fuse |
|
|