Thermostats are typically integral to the heater, encapsulated in silicone rubber and mounted in a heated area. The position is determined based upon application considerations, prototyping and testing.
Thermostats separate from heater and ambient sensing thermostats in several temperature ranges are also available.
Thermocouples, RTDs, thermistors and thermal fuses are normally mounted under a silicone rubber cap which is vulcanized to the heater sheath. The position can be anywhere on the heater surface.
 |
Adjustable Thermostat Temperature Ranges
70 - 140°F
70 - 190°F
70 - 425°F
|
120/240V
120/240V
120/240V
|
1600W Maximum
1600W Maximum
1600W Maximum
|
Thermostat can be wired separately when rating is exceeded. |
 |
|

|
 |
|
All items rated 125V/15A, 250V/10A.
Thermostat can be wired separately when rating is exceeded. Typically, the differential between the on and off position is 30°F.
Tolerance: ± 5°F open ± 8°F closed
Specify from the following values:
|
OPEN
|
CLOSE
|
|
OPEN
|
CLOSE
|
| 55°F |
40°F |
|
(ambient sensing only)
|
|
160°F
|
130°F
|
|
170°F
|
140°F
|
|
80°F
|
50°F
|
180°F
|
150°F
|
|
100°F
|
70°F
|
190°F
|
160°F
|
|
110°F
|
80°F
|
200°F
|
170°F
|
|
120°F
|
90°F
|
250°F
|
220°F
|
|
130°F
|
100°F
|
300°F
|
270°F
|
|
140°F
|
110°F
|
| 392°F |
365°F |
|
(hi-limit only)
|
|
|
150°F
|
120°F
|
| |